Tyron Power Services provides comprehensive Instrument Testing services as part of our Electrical Testing and Maintenance services. We perform Instrument Testing for industrial plants, large commercial facilities and municipal power stations. We are available 24 hours a day, seven days a week and are maintenance manager’s first choice for electrical testing, maintenance and repair.
Service Guarantee
TPS ’s mission is to provide the highest possible customer service at an affordable and affordable price that is beneficial to both our self and our clientele. Every Instrumentation testing and calibration testing performed by TPS is backed by our 100% customer satisfaction guarantee. If any instrument calibrated ever needs to recalibrated, TPS will gladly recalibrate the tool until it meets industry standards. Imprecise equipment can lead to costly errors that might be dangerous to employee safety. At TPS, we understand that our customer’s safety is the most important factor. Therefore, we strive to ensure that testing equipment is perfectly calibrated to the best of our ability. Our pledge is supported by our 35 year satisfactory customer service feedback and honest support by returning customers.
Calibration Services
For documentation and efficiency, we automate calibration procedures and record data. We can help you meet rigorous standards like the ISO 9000, FDA, EPA and OSHA regulations.
Equipment Calibration, Repair and Instrument Calibration:
- On-site and in shop calibration service
- Pick-up and delivery service
- ‘Rush – Next-On-Bench’ service available (call for details)
- Returning equipment to within manufacturer’s specifications
- Refurbishment services, returning your equipment to “like-new” conditions
- Replacement services, our wide range of affiliates and vast resources will be at your disposal
Our expert technicians and field engineers in conjunction with our state of the art equipment are able to calibrate, record, document, and in some cases revive obsolete equipment.
Our Outstanding On-Site Calibration Services Include:
- Pressure Transducers
- Differential Pressure
- Ultra-sonic Flow Meters
- Temperature Transducers
- Gas Detectors
- Level Transducers
- RTD Wells
Tyron Power Services Instrument Calibration Specifications
-
Measurement Accuracy
Voltage DC
110.000 mV 0.025%+0.015% *
1.10000 V 0.025%+0.005% *
11.0000 V 0.025%+0.005% *
110.000 V 0.05%+0.005% *
300.00 V 0.05%+0.005% *
Voltage AC
20 to 40 Hz 2% + 10
40 to 500 Hz 0.5% + 5
500 to 1 kHz 2% + 10
1 kHz to 5 kHz 10% + 20
Ranges: 1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA 0.01% + 0.015% *
110.00 mA 0.01% + 0.015% *
Resistance
11.000 Ω 0.05% + 50 mΩ
110.00 Ω 0.05% + 50 mΩ
1.1000 kΩ 0.05% + 500 mΩ
11.000 kΩ 0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz 0.05 Hz
110.0 to 1099.9 Hz 0.5 Hz
1.100 to 10.999 kHz 5 Hz
11.00 to 50.00 kHz 50 Hz
Pressure
Accuracy: from 0.025% of range using any of 29 pressure modules
Modules available for differential, gauge, vacuum
Absolute dual and high pressure
Note* (% of reading + % of full scale)
-
Source Accuracy
Voltage DC
110.000 mV 0.01%+0.005% *
1.10000 V 0.01%+0.005% *
15.0000 V 0.01%+0.005% *
Current DC
22.000 mA (Source) 0.01%+ 0.015% *
22.000 mA (Simulate) 0.02% + 0.03% *
Resistance
11.000 Ω 0.01% + 20 mΩ
110.00 Ω 0.01% + 40 mΩ
1.1000 kΩ 0.02% + 500 mΩ
11.000 kΩ 0.03% + 5Ω
Frequency
0.00 to 10.99 Hz 0.01 Hz
11.00 to 109.99 Hz 0.1 Hz
110.0 to 1099.9 Hz 0.1 Hz
1100 to 21999 Hz 2 Hz
22.000 to 50.000 kHz 5 Hz
Note* (% of reading + % of full scale)
RTDs and Thermocouples
-
Measure Accuracy:
10 Ω Cu (427): 2 °C
100 Ω Pt (3916): 0.3 °C
100 Ω Pt (3926): 0.3 °C
100 Ω Pt (385): 0.3 °C
200 Ω Pt (385): 0.3 °C
500 Ω Pt (385): 0.3 °C
1000 Ω Pt (385): 0.3 °C
120 Ω Ni (672): 0.3 °C
note: For 2-and 3-wire measurement, add 0.4°C
E: 0.3 °C
N: 0.5 °C
J: 0.3 °C
L: 0.3 °C
K: 0.3 °C
T: 0.3 °C
U: 0.3 °C
B: 0.9 °C
R: 1.0 °C
S: 0.9 °C
C: 0.6 °C
BP: 1.2 ºC
XK: 0.4 ºC
Note: Accuracy with external cold junction, for internal junction add 0.2°C
Technical Data
Data Log Functions
Measure functions: Voltage, current, resistance, frequency, temperature, pressure
Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature
Rate: 4 steps/second
Trip detect: Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage: Selectable, 24 V or 28 V
Accuracy: 5%
Maximum current: 22 mA, short circuit protected
Maximum input voltage: 30 V DC
-
Source Accuracy
10 Ω Cu (427): 1 °C
100 Ω Pt (3916): 0.1 °C
100 Ω Pt (3926): 0.1 °C
100 Ω Pt (385): 0.1 °C
200 Ω Pt (385): 0.1 °C
500 Ω Pt (385): 0.1 °C
1000 Ω Pt (385): 0.1 °C
120 Ω Ni (672): 0.1 °C
Note: For 2-and 3-wire simulation, add 0.4 °C
E: 0.2 °C
N: 0.3 °C
J: 0.2 °C
L: 0.2 °C
K: 0.3 °C
T: 0.3 °C
U: 0.3 °C
B: 0.8 °C
R: 0.9 °C
S: 0.9 °C
C: 0.6 °C
BP: 0.5 ºC
XK: 0.4 ºC
Note: Accuracy with external cold junction, for internal junction add 0.2°C
Step Functions
Source Functions: Voltage, current, resistance, frequency, temperature
Environmental Specifications
Operating Temperature
-10 °C to +50 °C -20 °C to +50 °C *
Storage Temperature
-20 °C to +60 °C
Dust/water resistance
Meets IP52, IEC 529
Operating Altitude
2800 m
Note: * Except frequency and AC
Tyron Power Services Providing Instrument Testing To California And Nationwide
With offices in Abuja, Tyron Power Services provides Instrument Testing services to clients throughout Nigeria including Lagos, Port Harcourt and Aba as well as Lokoja. We serve industrial, commercial and municipal clients in various industries including power stations, power plants, wind and solar, petro-chemicals, manufacturing, hotels, hospitals, municipalities, defense contractors, data centers and many other applications that rely on high power electric equipment. Whatever your Instrument Testing needs may be, contact us and we will make sure that your equipment is treated with the care and safety requirements that it deserves. See our full line of electrical testing.